CASE REPORTS

DR-FRANCK-LASRY
Dr. FRANCK LASRY // FRANCE

Immediate Loading after Extraction-Implantation // CASE 1

Central right and left replaced.

Fig 1,2 Simulation of implant and verification of residual bone FL. Fig 3, 4 Titanium post are used to drive implants in position after drilling sequence. They can be used as permanent post In this case they are removed and replaced by TAV Dental Zirconium abutments. Fig 5 Due to drilling sequence, related with roots axis, one angulated and one straight abutment are used. Fig 6, 7 Special Diamond bur is given with each abutment to avoid pollution of zirconium TAV. Fig 8 Hight speed micromotor and flushing is used to adjust shape and length. Fig 9 Due to emmergency lab temps could not be done. Two Directa acrylic temp and self curing resin are used. Diastema was a special request from the patient. Fig 10 Great effort is taken to adjust cervical shape and polishing, to prevent periodontal problem. The crowns are NOT cemented to avoid cement irritation under gingiva.